sales@cimtec.com 3915 Shopton Rd Suite 103, Charlotte, NC 28217 877.524.6832

Safe Series Connection

The safe series connection enables the connection of up to 32 safety sensors up to performance level e. You can wire safety switches and safety sensors with OSSD outputs in the mix, regardless of the manufacturer. Selected detailed diagnostic information is also available for each sensor or switch.

FLN-OSSD1100108

Safe series connection Flexi Loop

  • Flexi Loop component: Node for safety sensors (OSSD)
  • Use of Flexi Loop node: For safety sensor with dual-channel OSSD outputs, With standard input, with standard output
  • Connection type safety device: Female connector M12, 8-pin

FLN-OSSD1000105

Safe series connection Flexi Loop

  • Flexi Loop component: Node for safety sensors (OSSD)
  • Use of Flexi Loop node: For safety sensor with dual-channel OSSD outputs, With standard input
  • Connection type safety device: Female connector M12, 5-pin

FLN-EMSS0000105

Safe series connection Flexi Loop

  • Flexi Loop component: Node for safety switch (EMSS)
  • Use of Flexi Loop node: For dual-channel equivalent electro-mechanical safety switch (EMSS)
  • Connection type safety device: Female connector M12, 5-pin

FLN-EMSS1100108

Safe series connection Flexi Loop

  • Flexi Loop component: Node for safety switch (EMSS)
  • Use of Flexi Loop node: For dual-channel equivalent electro-mechanical safety switch (EMSS), With standard input, with standard output
  • Connection type safety device: Female connector M12, 8-pin

FLT-TERM00001

Safe series connection Flexi Loop

  • Flexi Loop component: Module to terminate series connection
  • Description: The terminator is used to terminate the safe series connection at the last Flexi Loop node.

FLA-PWRI00001

Safe series connection Flexi Loop

  • Flexi Loop component: Module for energy supply
  • Description: The power supply module is used to connect a power supply with 24 V DC, for the electrical isolation and for overcurrent shutdown.

FLA-MSTR00001

Safe series connection Flexi Loop

  • Flexi Loop component: Module for connection to Flexi Classic
  • Description: Flaxi Loop master node to connect a Flexi Loop cascade to Flexi Classic. System diagnostics during operation and during commisioning without busmaster.
 

FLA-MSTR00002

Safe series connection Flexi Loop

  • Flexi Loop component: Module for connection to Flexi Classic
  • Description: Flaxi Loop master node to connect a Flexi Loop cascade to Flexi Classic. System diagnostics during operation and during commisioning without busmaster.
  • Additional interfaces: IO-Link

FLA-DIAG00001

Safe series connection Flexi Loop

  • Flexi Loop component: Module for field diagnostics
  • Description: The diagnostics module is used as a commissioning aid and to display the Flexi Loop states during operation.

FLA-YCON00002

Safe series connection Flexi Loop

  • Flexi Loop component: Y-adapter
  • Description: The Flexi Loop Y-adapter (OSSD) splits the 8-pin connection of the FLN-OSSD1100108 in two 5-pin connections: One for safety sensors with dual-channel OSSD outputs and one for non-safe I/O signals.

FLA-YCON00001

Safe series connection Flexi Loop

  • Flexi Loop component: Y-adapter
  • Description: The Flexi Loop Y-adapter (EMMS) splits the 8-pin connection of the FLN-EMSS1100108 in two 5-pin connections: One for dual-channel equivalent electro-mechanical safety switches and one for non-safe I/O signals.

Speak with a Dedicated CIMTEC Represenative

CIMTEC has developed an extensive product offering through partnerships with industry leading manufacturers. With extensive experience in the industry, count on us to meet your needs while improving your facility’s operation and efficiency.

Need to speak with someone immediately?

Call us at
877.524.6832